Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Ferroli Fault code Ferroli
F62

Calibration needed or combustion fault

Blocking: it retries by itself

On a Bluehelix Alpha or HiTech RRT the boiler asks for a calibration, because its circuit board is new or the calibration has not been done yet; on a Bluehelix Top RRT the combustion is abnormal, for example because of too low a gas pressure, an unstable mains voltage or a badly placed electrode. The boiler stops temporarily; the calibration or the combustion check needs our technician.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F62?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F62

The meaning depends on the boiler: find yours below.

F62

Calibration request

Blocking: it retries by itself Bluehelix Alpha, Bluehelix HiTech RRT C
F62

Combustion fault

Blocking: it retries by itself Bluehelix Top RRT K 50

What our technician checks

  • The calibration: full manual (Bluehelix Alpha) or AUTO SETUP (Bluehelix HiTech RRT)
  • Bluehelix Top RRT: the gas supply pressure
  • Bluehelix Top RRT: the mains supply voltage
  • Bluehelix Top RRT: the ignition and earth electrode
  • Bluehelix Top RRT: a 10-second power cut, resetting the fault and a 100 % calibration (Sc15 = 1)

Related codes