Calibration needed or combustion fault
Blocking: it retries by itself
On a Bluehelix Alpha or HiTech RRT the boiler asks for a calibration, because its circuit board is new or the calibration has not been done yet; on a Bluehelix Top RRT the combustion is abnormal, for example because of too low a gas pressure, an unstable mains voltage or a badly placed electrode. The boiler stops temporarily; the calibration or the combustion check needs our technician.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F62?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F62
The meaning depends on the boiler: find yours below.
Calibration request
Combustion fault
What our technician checks
- The calibration: full manual (Bluehelix Alpha) or AUTO SETUP (Bluehelix HiTech RRT)
- Bluehelix Top RRT: the gas supply pressure
- Bluehelix Top RRT: the mains supply voltage
- Bluehelix Top RRT: the ignition and earth electrode
- Bluehelix Top RRT: a 10-second power cut, resetting the fault and a 100 % calibration (Sc15 = 1)