Ferroli Fault code Ferroli
F56

Calibration failed or not completed

Blocking: it retries by itself

On a Bluehelix Top RRT K 50, the calibration the boiler runs by itself to set its combustion has failed or could not finish: wrong parameters, electrode badly placed or disconnected, flue gases recirculating inside the boiler, or too little water circulation or heat drawn off during the calibration. It is a temporary block: the boiler starts again by itself once the fault is gone.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F56?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F56

The meaning depends on the boiler: find yours below.

F56

Calibration fault / Calibration procedure not completed

Blocking: it retries by itself Bluehelix Top RRT K 50

What our technician checks

  • The parameters, then a 100% calibration
  • The electrode position, replaced if needed, then a new 100% calibration
  • The tightness of the flue duct and of the seals
  • A new calibration with a hot water tap open, until the flame stops flashing (about 2 minutes)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.