Water pressure switch, settings or high pressure
Breakdown: the boiler is stopped
The meaning depends on the boiler: on a Bluehelix Alpha the water pressure switch or pressure sensor is configured wrongly or reports a pressure out of range; on a Bluehelix Top RRT a circuit board parameter is set wrongly; on a Bluehelix HiTech RRT the water pressure was too high more than three times in 24 hours (code F40). In every case the boiler locks out and only restarts after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show A26?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code A26
The meaning depends on the boiler: find yours below.
Water pressure switch fault
Board parameter fault
Fault F40 occurred more than 3 times in 24h
What our technician checks
- Bluehelix Alpha: the setting of parameter b04 (0 = pressure switch, default) and the pressure measured by the transducer
- Bluehelix Top RRT: the circuit board parameters, corrected if needed
- Bluehelix HiTech RRT: the system pressure, brought back to 1 to 1.5 bar by partial draining
- Bluehelix HiTech RRT: the expansion vessel, recharged or replaced