Ferroli Fault code Ferroli
A23

Filling too long, settings or pressure sensor

Breakdown: the boiler is stopped

The meaning depends on the boiler: on a Bluehelix Alpha, automatic filling of the system through the solenoid valve took more than 5 minutes, a sign of a leak; on a Bluehelix Top RRT a circuit board parameter is set wrongly; on a Bluehelix HiTech RRT the system pressure sensor is configured wrongly or reports a pressure out of range. In every case the boiler locks out and only restarts after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show A23?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code A23

The meaning depends on the boiler: find yours below.

A23

System filling, with par. b07 = 2, more than 5 minutes.

Breakdown: the boiler is stopped Bluehelix Alpha
A23

Board parameter fault

Breakdown: the boiler is stopped Bluehelix Top RRT K 50
A23

Pressure sensor fault

Breakdown: the boiler is stopped Bluehelix HiTech RRT C

What our technician checks

  • Bluehelix Alpha: the system (leak) and the filling valve
  • Bluehelix Top RRT: the circuit board parameters, corrected if needed
  • Bluehelix HiTech RRT: the setting of parameter b04 and the pressure measured by the transducer

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.