Ferroli Fault code Ferroli
A11

Return sensor or gas valve fault

Breakdown: the boiler is stopped

On a Bluehelix Top RRT K 50, A11 means a fault of the return water temperature sensor (damaged sensor, short-circuited or broken wiring); on a Bluehelix HiTech RRT C, the gas valve is no longer properly connected (connector unplugged, electrical connection broken or valve damaged). In both cases the boiler locks out and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show A11?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code A11

The meaning depends on the boiler: find yours below.

A11

Return sensor fault

Breakdown: the boiler is stopped Bluehelix Top RRT K 50
A11

Gas valve connection

Breakdown: the boiler is stopped Bluehelix HiTech RRT C

What our technician checks

  • The return sensor wiring, or the sensor, to be replaced (Bluehelix Top RRT K 50)
  • The gas valve connector, properly plugged in (Bluehelix HiTech RRT C)
  • The wiring between the control unit and the gas valve (Bluehelix HiTech RRT C)
  • The gas valve, to be replaced if damaged (Bluehelix HiTech RRT C)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.