Daikin Fault code Daikin
UA

Combination or communication problem between units

Breakdown: the boiler is stopped

Code UA reports that parts of the heat pump are not correctly matched or do not communicate; on a Daikin Altherma 3 (H HT, H MT, R, H or M) or an Altherma LT split or monobloc, the number shown next to it says which, depending on the model: 00 indoor and outdoor units do not match, 16 communication between the extension and the hydrobox (on the Altherma LT monobloc, between the hydro part and the control box), 17 domestic hot water tank type, 21 extension and hydrobox do not match, 22 communication between the control box and the option box (Altherma 3 H, Altherma LT monobloc) or extension and hydrobox do not match (Altherma 3 R 3 kW, ERLA03), 59 HPSU/hydro combination (ECH₂O); on an Altherma LT with an EKHBH/EKHBX or EKHVH/EKHVX indoor unit, UA is a communication failure, and on an Altherma HT (EKHBRD), a type connection problem, which can show until the initialisation between outdoor and indoor unit is finished: after power-on, the manual says to wait at least 12 minutes. Apart from that case, it is a fault for our technician to correct: Daikin leaves resetting an error code to an installer or the dealer.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show UA?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code UA

The small number shown beside the code tells which.

UA

Communication failure

Breakdown: the boiler is stopped Altherma LT EKHB/EKHV
UA

Type connection problem

Breakdown: the boiler is stopped Altherma HT
UA
00

Indoor unit, outdoor unit matching problem

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R, Altherma LT monobloc, Altherma LT split
UA
16

Extension/hydro communication problem

Breakdown: the boiler is stopped Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R, Altherma LT monobloc, Altherma LT split
UA
17

Tank type problem

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R, Altherma LT split
UA
21

Extension/hydro mismatch problem

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R, Altherma LT split
UA
22

Communication problem between control box and option box

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 R, Altherma LT monobloc
UA
59

HPSU/Hydro combination abnormality

Breakdown: the boiler is stopped Altherma 3 H HT, Altherma 3 H MT, Altherma 3 R

What our technician checks

  • UA-00: the indoor and outdoor unit combination
  • UA-16: the communication between the extension and the hydrobox (Altherma LT monobloc: hydro part and control box)
  • UA-17: the domestic hot water tank type set; Altherma LT split: settings [E-05], [E-07], [D-02] and the recirculation pump
  • UA-21: the match between the extension and the hydrobox (UA-22 on the Altherma 3 R 3 kW)
  • UA-22: the communication between the control box and the option box (Altherma 3 H, Altherma LT monobloc)
  • UA-59: the HPSU/hydro combination (ECH₂O)
  • Altherma HT: the end of the initialisation between outdoor and indoor unit
  • Altherma LT EKHBH/X, EKHVH/X: the communication

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.