Viessmann Fault code Viessmann
F.875

Lost link with the lead boiler (cascade)

Blocking: it retries by itself

In a cascade (several boilers linked together), this boiler no longer communicates with the lead appliance that controls it. The cascade keeps running, but in a limited way, until our technician restores the link.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.875?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.875

The meaning depends on the boiler: find yours below.

F.875

Communication fault of the connected main appliance

Blocking: it retries by itself Vitodens One Base

What our technician checks

  • The CAN bus connection at plug 91 of the HMU electronic module
  • The connections to the other CAN bus devices
  • Plug seating, contact corrosion and the condition of the cables
  • The CAN L / CAN H assignment, with CAN Ground left unconnected
  • The cable type and length (shielded twisted pair or shielded CAT5)
  • The position and number of terminating resistors