The monitoring thermostat has tripped
Blocking: it retries by itself
The monitoring thermostat, which limits the maximum heating water temperature, has tripped. It is a warning: our technician needs to find out why the water in the system got too hot.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show A.19?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code A.19
The meaning depends on the boiler: find yours below.
The monitoring aquastat has tripped
What our technician checks
- The hydraulic scheme set, the time program and the temperature levels
- The internal and external shut-off devices, all open
- Venting the boiler circuit and the system pressure
- The internal diverter valve in the relay test, and its cable set
- The central pump and its cable set
- The temperature sensors (hot water or low-loss header, flow) and their resistance
- Fouling of the internal parts and the quality of the fill water
- The system's dirt traps and sludge and magnetite separators