Electrical fault in the heating pump
Blocking: it retries by itself
The boiler detects an electrical fault on the pump of heating circuit 1, so the water no longer circulates. Without that flow it cannot heat the rooms or make hot water until the pump works again.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.799?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.799
The meaning depends on the boiler: find yours below.
Electrical fault of heating circuit 1 circulation pump
What our technician checks
- The system's fuse protection
- The 230 V (X18, plug 20) and PWM (X3.7, X3.9) connections on the BCU burner control unit
- Plug seating, contact corrosion and the condition of the cables
- The pump's operation in the relay test (HMI or ViGuide)
- The pump, to be replaced