No communication with the additional appliance
Breakdown: the boiler is stopped
On a Vitodens One Base (200-W B2HF or B2KF, 222-F B2TF, 222-W B2LF, 242-F), the boiler (main appliance) no longer communicates with the additional appliance connected to it over the CAN bus. The installation goes into fault: our technician needs to check the link.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.765?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.765
The meaning depends on the boiler: find yours below.
Communication fault of the connected additional appliance
What our technician checks
- The connection on plug 91 of the HMU electronics module
- The connection to the other CAN bus participants: plug, wires, contact corrosion, damaged cables
- The cable type (only one type within a CAN bus system) and the cable length
- The CAN terminating resistor
- The component concerned on the additional appliance, replaced if needed