Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Viessmann Fault code Viessmann
F.694

Flue gas safety limiter: signals disagree

Breakdown: the boiler is stopped

On a Vitodens One Base (200-W B2HF or B2KF, 222-F B2TF, 222-W B2LF, 242-F), the signal comparison shows a discrepancy with the flue gas safety temperature limiter. It is a fault: the burner stops and the boiler only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F.694?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.694

The meaning depends on the boiler: find yours below.

F.694

Flue gas safety cut-out deviation

Breakdown: the boiler is stopped Vitodens One Base

What our technician checks

  • The connection between the burner control unit BCU and the flue gas temperature sensor: plug, wires, contact corrosion, damaged cables
  • The sensor's resistance (NTC 10 kΩ) at the unplugged connector, compared with the manual's curve
  • The flue and air intake duct, dirty or blocked
  • The flue gas temperature sensor, replaced if needed, then unlocking

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.