Ionisation current out of range (fault logged)

Blocking: it retries by itself

The ionisation current, the flame signal the boiler uses to control its combustion, went out of the allowed range. The boiler keeps running and the fault is stored in its fault history; if it comes back, our technician needs to check the ionisation electrode, the gas valve and the fan unit.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.69?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.69

The meaning depends on the boiler: find yours below.

F.69

Ionisation current outside the valid range

Blocking: it retries by itself Vitodens One Base

What our technician checks

  • Whether the insulating block touches the ionisation electrode ceramic
  • The combined gas valve, with about 4 minutes at minimum output in the relay test (BCU replaced if the fault appears)
  • Modulation from minimum to maximum output and fouling of the inlet strainer
  • The fan unit, replaced if needed