Flame signal already present at start
Breakdown: the boiler is stopped
As the burner starts, the boiler already detects a flame signal although there should be no flame yet (stray light). The burner goes into fault: the boiler stops heating and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.68?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.68
The meaning depends on the boiler: find yours below.
Extraneous light
What our technician checks
- The flame signal with the gas valve closed and the ionisation electrode cable unplugged
- The BCU burner control unit, replaced if the message persists