F.67

Ionisation current out of range

Breakdown: the boiler is stopped

The ionisation current, the flame signal the boiler uses to control its combustion, is out of the allowed range: the cause is the gas supply, the gas valve or the ionisation electrode (gap, fouling). The burner goes into fault: the boiler stops heating and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F.67?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.67

The meaning depends on the boiler: find yours below.

F.67

Ionisation current outside the valid range

Breakdown: the boiler is stopped Vitodens One Base

What our technician checks

  • The gas supply: gas pressure and gas flow monitor
  • The combined gas valve and its inlet strainer
  • The ionisation electrode: gap to the burner grid
  • Fouling of the ionisation electrode and the burner grid
  • The fan unit, replaced if the message persists