Ionisation current out of range
Breakdown: the boiler is stopped
The ionisation current, the flame signal the boiler uses to control its combustion, is out of the allowed range: the cause is the gas supply, the gas valve or the ionisation electrode (gap, fouling). The burner goes into fault: the boiler stops heating and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.67?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.67
The meaning depends on the boiler: find yours below.
Ionisation current outside the valid range
What our technician checks
- The gas supply: gas pressure and gas flow monitor
- The combined gas valve and its inlet strainer
- The ionisation electrode: gap to the burner grid
- Fouling of the ionisation electrode and the burner grid
- The fan unit, replaced if the message persists