Hot water preheating sensor TS3 open circuit
Blocking: it retries by itself
On a Vitodens One Base (200-W B2HF or B2KF, 222-F B2TF, 222-W B2LF, 242-F), with a solar installation, sensor TS3 for preheating the domestic hot water is open circuit. The boiler keeps running, but the solar preheating function, the preheating of the second cylinder and the solar destratification pump are out of action: our technician needs to check the sensor.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.666?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.666
The meaning depends on the boiler: find yours below.
Open circuit of DHW preheating sensor TS3
What our technician checks
- The TS3 sensor connection (plug 7) on the SDIO electronics module: plug, wires, contact corrosion, damaged cables
- The sensor's resistance (NTC 10 kΩ) at the unplugged connector, compared with the manual's curve
- The sensor, replaced if needed