Flue gas temperature limiter tripped
Breakdown: the boiler is stopped
The flue gas temperature limiter has tripped; the causes to check are mainly on the water side: filling level, expansion vessel, flow, diverter valve or air in the system. The burner goes into fault: the boiler stops heating and can only be reset once the flue has cooled down.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system pressure: if it is below 1.0 bar, top up with water or call us.
- Do not reset the boiler: call us.
Does your boiler show F.63?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.63
The meaning depends on the boiler: find yours below.
The flue gas temperature limiter has tripped
What our technician checks
- The filling level of the system
- The expansion vessel pre-charge, matched to the system pressure
- The water flow: flow sensor and circulation pump
- The 3-way diverter valve (relay test)
- Bleeding air from the system