Viessmann Fault code Viessmann
F.574

Circuit 1 room sensor not available

Blocking: it retries by itself

On a Vitodens One Base (200-W B2HF or B2KF, 222-F B2TF, 222-W B2LF, 242-F), the control finds no room temperature sensor in heating circuit 1. The boiler keeps heating, but without taking the room temperature into account: our technician needs to check the sensor and its setting.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.574?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.574

The meaning depends on the boiler: find yours below.

F.574

Room temperature sensor HC 1 not available

Blocking: it retries by itself Vitodens One Base

What our technician checks

  • Whether a room temperature sensor is fitted on this circuit
  • Parameter 933.6, and parameter 933.7 to be set again if needed
  • The sensor connection (NTC 10 kΩ): plug, wires, contact corrosion, damaged cables
  • The sensor's resistance (NTC 10 kΩ) at the unplugged connector, compared with the manual's curve