Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Viessmann Fault code Viessmann
F.57

Room temperature sensor open circuit

Blocking: it retries by itself

The boiler no longer receives the room temperature, measured by the Vitotrol 200-E remote control or by its external room sensor. The boiler keeps heating, but without taking the room temperature into account, until our technician has repaired the fault.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.57?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.57

The meaning depends on the boiler: find yours below.

F.57

Open circuit of the room temperature sensor

Blocking: it retries by itself Vitodens One Base

What our technician checks

  • The external room sensor settings on the Vitotrol 200-E, and recommissioning it if needed
  • Whether an external sensor is connected to terminals 3 and 4 of the Vitotrol 200-E
  • Terminals 13c and 9 of the external sensor, 3 and 4 of the Vitotrol 200-E, plug 74 or terminals 5 and 6 on the boiler, and the cable
  • The resistance of the external sensor (NTC 10 kΩ) at terminals 13c and 9
  • The Vitotrol 200-E, its wall base and then its control unit, replaced if needed

Related codes