Viessmann Fault code Viessmann
F.547

Circuit 3 flow sensor short-circuited

Blocking: it retries by itself

On a Vitodens One Base (200-W B2HF or B2KF, 222-F B2TF, 222-W B2LF, 242-F), the flow temperature sensor of heating circuit 3 (mixing valve circuit) is short-circuited. The boiler keeps running, but that circuit's mixing valve closes while its pump keeps running: the circuit no longer heats properly and our technician needs to check the sensor.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.547?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.547

The meaning depends on the boiler: find yours below.

F.547

Short circuit of flow temperature sensor HC 3

Blocking: it retries by itself Vitodens One Base

What our technician checks

  • The setting of rotary switch S1 on the ADIO electronics module (mixing valve extension)
  • The flow sensor and its connection on the ADIO module: plug, wires, contact corrosion, damaged cables
  • The sensor's resistance (NTC 10 kΩ) at the unplugged connector, compared with the manual's curve
  • The ADIO electronics module, to be replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.