Viessmann Fault code Viessmann
F.468

Flame signal too high during calibration

Breakdown: the boiler is stopped

On a Vitodens One Base (200-W B2HF or B2KF, 222-F B2TF, 222-W B2LF, 242-F), during the automatic combustion calibration the ionisation current, which monitors the flame, is too high. It is a fault: the burner stops and the boiler only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Keep paint, solvent and cleaning product fumes, and building dust, away from the boiler.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F.468?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.468

The meaning depends on the boiler: find yours below.

F.468

Ionisation current too high during calibration

Breakdown: the boiler is stopped Vitodens One Base

What our technician checks

  • The gap between the ionisation electrode and the burner gauze
  • Dust in the supply air, for example from building work
  • The cause of deposits on the electrodes, in the boiler room and the flue system (detergents, cleaning products, toiletries)
  • After replacing the gauze and the electrode, the fan unit, the gas-air duct and the Venturi extension, to be cleaned

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.