Viessmann Fault code Viessmann
F.467

Gas supply too low during calibration

Breakdown: the boiler is stopped

On a Vitodens One Base (200-W B2HF or B2KF, 222-F B2TF, 222-W B2LF, 242-F), the gas supply is too low during the automatic combustion calibration, for example because the gas pipe is dirty or too small. It is a fault: the burner stops and the boiler only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the gas supply valve is open; if it is, ask your gas supplier (on propane, check the tank level).
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F.467?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.467

The meaning depends on the boiler: find yours below.

F.467

Insufficient gas supply during calibration

Breakdown: the boiler is stopped Vitodens One Base

What our technician checks

  • The static and dynamic gas pressure
  • The sizing of the gas pipe and the gas flow monitor
  • The gas valve inlet and its inlet strainer, checked visually for dirt (for example after the gas pipe was brazed)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.