Gas supply too low during calibration
Breakdown: the boiler is stopped
On a Vitodens One Base (200-W B2HF or B2KF, 222-F B2TF, 222-W B2LF, 242-F), the gas supply is too low during the automatic combustion calibration, for example because the gas pipe is dirty or too small. It is a fault: the burner stops and the boiler only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the gas supply valve is open; if it is, ask your gas supplier (on propane, check the tank level).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.467?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.467
The meaning depends on the boiler: find yours below.
Insufficient gas supply during calibration
What our technician checks
- The static and dynamic gas pressure
- The sizing of the gas pipe and the gas flow monitor
- The gas valve inlet and its inlet strainer, checked visually for dirt (for example after the gas pipe was brazed)