Flame signal weak and implausible during calibration
Breakdown: the boiler is stopped
On a Vitodens One Base (200-W B2HF or B2KF, 222-F B2TF, 222-W B2LF, 242-F), during the automatic combustion calibration the ionisation current, which monitors the flame, is too low and its difference from the last measurement is not plausible. It is a fault: the burner stops and the boiler only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Keep paint, solvent and cleaning product fumes, and building dust, away from the boiler.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.464?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.464
The meaning depends on the boiler: find yours below.
Ionisation current too low during calibration. Difference from the previous value not plausible
What our technician checks
- The ionisation electrode and its cable, plug connections free of loose contacts
- Dust in the supply air, for example from building work
- The flue system, with no flue gas recirculation
- Condensate building up in the installation
- The burner control unit BCU, to be replaced if the message comes back after unlocking
- The burner gauze and the ionisation electrode, replaced if needed (fan unit removed before the burner)
- After replacing the gauze and the electrode, the fan unit, the gas-air duct and the Venturi extension, to be cleaned
- The cause of deposits on the electrodes, in the boiler room and the flue system (detergents, cleaning products, toiletries)