Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Viessmann Fault code Viessmann
F.463

Flame signal too weak during calibration

Breakdown: the boiler is stopped

On a Vitodens One Base (200-W B2HF or B2KF, 222-F B2TF, 222-W B2LF, 242-F), during the automatic combustion calibration the ionisation current, which monitors the flame, is too low, for example because the combustion air is dirty or flue gas is being drawn back in. It is a fault: the burner stops and the boiler only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Keep paint, solvent and cleaning product fumes, and building dust, away from the boiler.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F.463?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.463

The meaning depends on the boiler: find yours below.

F.463

Ionisation current too low during calibration

Breakdown: the boiler is stopped Vitodens One Base

What our technician checks

  • The flue system: dirt and flue gas recirculation, cleaned if needed
  • The burner gauze and the ionisation electrode, replaced if needed
  • After replacing the gauze and the electrode, the fan unit, the gas-air duct and the Venturi extension, to be cleaned
  • The cause of deposits on the electrodes, in the boiler room and the flue system (detergents, cleaning products, toiletries)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.