Flame signal missing or too weak
Breakdown: the boiler is stopped
The boiler detects no flame at its burner, or too weak a flame signal. The burner has locked out for safety and the boiler stops heating until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the gas supply valve is open and, on propane, that there is gas left in the tank.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.379?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.379
The meaning depends on the boiler: find yours below.
Flame signal absent or too weak
What our technician checks
- The gas shut-off valves, fully open
- The static and flowing gas pressure
- The gas pipe and the gas flow limiter: sizing and operation
- The ionisation electrode: wear, deformation, damage, replaced if needed
- The ionisation electrode's cable and plug
- The ignition electrode: wear, deformation, gap, replaced if needed
- The burner gauze: fouling, damage