Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Viessmann Fault code Viessmann
F.379

Flame signal missing or too weak

Breakdown: the boiler is stopped

The boiler detects no flame at its burner, or too weak a flame signal. The burner has locked out for safety and the boiler stops heating until it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the gas supply valve is open and, on propane, that there is gas left in the tank.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F.379?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.379

The meaning depends on the boiler: find yours below.

F.379

Flame signal absent or too weak

Breakdown: the boiler is stopped Vitodens One Base

What our technician checks

  • The gas shut-off valves, fully open
  • The static and flowing gas pressure
  • The gas pipe and the gas flow limiter: sizing and operation
  • The ionisation electrode: wear, deformation, damage, replaced if needed
  • The ionisation electrode's cable and plug
  • The ignition electrode: wear, deformation, gap, replaced if needed
  • The burner gauze: fouling, damage

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.