Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Viessmann Fault code Viessmann
F.378

Flame lost during the stabilisation phase

Breakdown: the boiler is stopped

The burner lit, then the flame went out during the stabilisation phase that follows ignition. The burner has locked out for safety and the boiler stops heating until it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the gas supply valve is open and, on propane, that there is gas left in the tank.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F.378?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.378

The meaning depends on the boiler: find yours below.

F.378

Loss of flame during the stabilisation or operating phase

Breakdown: the boiler is stopped Vitodens One Base

What our technician checks

  • The gas supply: pressure, gas flow limiter, valves
  • How the ionisation electrode and its seal are fitted
  • Fouling of the ionisation electrode and the burner gauze
  • How the ignition electrode and its seal are fitted
  • The burner gauze, insulation ring and block, and the heat exchanger
  • Flue gas recirculation in the flue and air supply ducts
  • The condensate drain and trap: damage, blockage, deformation

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.