Ionisation current recalibration not possible
Breakdown: the boiler is stopped
The boiler could not reach the stable conditions needed to recalibrate its ionisation current, the flame signal it uses to adjust combustion. The burner goes to fault and the boiler only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.377?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.377
The meaning depends on the boiler: find yours below.
Reprocessing of the ionisation current calibration: stabilisation conditions for a…
What our technician checks
- The gas type setting
- The gap between the ionisation electrode and the burner grid
- The flue system, with no flue gas recirculation
- The burner control unit BCU, replaced if the fault comes back