Repeated flame loss during calibration
Breakdown: the boiler is stopped
During the automatic calibration the boiler runs regularly to set its combustion, the flame went out several times. The burner has locked out for safety and the boiler stops heating until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Avoid polluting the air in the boiler room (paints, solvents, cleaning products).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.372?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.372
The meaning depends on the boiler: find yours below.
Repeated loss of flame during calibration
What our technician checks
- The ionisation electrode and its cable
- The plug connections (loose contacts)
- The flue system and flue gas recirculation
- Condensate build-up in the system
- The inlet and strainer of the gas combination valve (fouling)
- Deposits on the electrodes and their cause in the boiler room and flue system
- If the gauze and ionisation electrode are replaced: the fan unit, gas-air duct and Venturi extension, cleaned