No flame signal at burner start
Breakdown: the boiler is stopped
When the burner starts, the boiler detects no flame, or too weak a flame signal. The burner has locked out for safety and the boiler stops heating until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Avoid polluting the air in the boiler room (paints, solvents, cleaning products).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.361?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.361
The meaning depends on the boiler: find yours below.
The flame signal is absent or too weak when the burner starts
What our technician checks
- The ionisation electrode and its cable
- The plug connections (loose contacts)
- Deposits on the electrodes and their cause in the boiler room and flue system (detergents, cleaning or personal care products)