Insufficient gas supply
Breakdown: the boiler is stopped
The boiler is not getting enough gas to run its burner. The burner has locked out for safety and the boiler stops heating until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the gas supply valve is open and, on propane, that there is gas left in the tank.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.357?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.357
The meaning depends on the boiler: find yours below.
Insufficient gas supply
What our technician checks
- The gas supply valves, all open
- The inlet strainer of the gas combination valve, cleaned
- The static and flowing gas pressure
- The fan unit cable, if the static pressure does not drop
- The gas pipe and the gas flow limiter: sizing and operation
- The ignition electrode: wear, deformation, gap, replaced if needed
- The house pressure regulator, if the pressure rises when the burner is off
- The fan unit, replaced if needed