Internal CO limit exceeded
Breakdown: the boiler is stopped
The burner has locked out for safety because the boiler's internal carbon monoxide (CO) limit was exceeded. The boiler stops heating until it is reset, and our technician needs to find the cause.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Do you smell flue gas? Switch the boiler off, air the room it is in and close the doors to the living areas.
- Do not reset the boiler: call us.
Does your boiler show F.352?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.352
The meaning depends on the boiler: find yours below.
Internal air/gas ratio
What our technician checks
- The whole flue gas path: recirculation, leaks, water pocket, narrowing, blockage
- Servicing of the flue system, if needed
- Plug 54 on the burner control unit (BCU): seating, corrosion, cables
- The BCU's ignition voltage (plug X18.1/3)
- The ionisation electrode: gap, fouling, connection
- The burner control unit (BCU), to be replaced