Ionisation voltage fault
Breakdown: the boiler is stopped
The ionisation current, the flame signal the boiler uses to control its combustion, is out of the allowed range; the checks here cover the connection, the ignition voltage and the burner control unit. The burner goes into fault: the boiler stops heating and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.350?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.350
The meaning depends on the boiler: find yours below.
Ionisation voltage
What our technician checks
- Plug 54 on the BCU burner control unit
- Seating of plugs and wires, contact corrosion and cable condition
- The BCU ignition voltage at plug X18.1/3
- The ionisation electrode: gap, fouling and connection
- The BCU burner control unit, to be replaced