Temperature monitor tripped
Blocking: it retries by itself
The boiler's temperature monitor has tripped; the causes to check are mainly on the water side: closed valves, air, pressure, diverter valve, circulation pump or temperature sensor. The burner is blocked and the boiler restarts by itself once it has cooled down.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system pressure: if it is below 1.0 bar, top up with water or call us.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.345?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.345
The meaning depends on the boiler: find yours below.
The monitoring aquastat has tripped
What our technician checks
- The hydraulic scheme set, the time programmes and the temperature levels
- Whether all internal and external shut-off valves are open
- Bleeding the boiler circuit and the system pressure
- The internal diverter valve (relay test) and its cable to plug X3 of the BCU
- The central circulation pump (full load with the PWM signal unplugged) and its cable, or the BCU
- The hot water, low loss header or buffer and flow sensors: connections, fitting, resistance (NTC 10 kΩ)
- Fouling of internal parts (pipework, heat exchanger, pump, bypass valve) and the water quality
- The dirt trap and the sludge and magnetite separators of the system