Low loss header sensor open circuit
Blocking: it retries by itself
The flow temperature sensor of the low loss header gives no signal: the sensor or its cable is broken. The boiler keeps heating without this sensor until our technician has repaired the fault.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.29?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.29
The meaning depends on the boiler: find yours below.
Open circuit of the low loss header sensor
What our technician checks
- The « Low loss header » setting in the commissioning assistant
- Connection TS3 (plug 9) on the ADIO electronic module (EM-M1 or EM-P1 extension)
- Seating of plugs and wires, contact corrosion and cable condition
- The sensor resistance (NTC 10 kΩ), compared with its curve