Safety temperature limiter open circuit
Breakdown: the boiler is stopped
The dual sensor that measures the flow temperature and acts as the safety temperature limiter gives no signal: the sensor or its cable is broken. The burner goes into fault: the boiler stops heating and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.185?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.185
The meaning depends on the boiler: find yours below.
Open circuit of the safety temperature limiter
What our technician checks
- The connections and plug X1 (plug 3/3A) on the BCU burner control unit, and the cable
- Seating of plugs and wires, contact corrosion and cable condition
- The resistance (NTC 10 kΩ) of each flow sensor of the dual sensor, compared with its curve
- The BCU burner control unit, to be replaced