Gas pressure too low
Breakdown: the boiler is stopped
The gas pressure reaching the boiler is too low: gas supply valve closed, air in the gas line, too low a pressure on the supplier's network or a fouled gas valve. The burner goes into fault: the boiler stops heating and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas supply valve is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.180?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.180
The meaning depends on the boiler: find yours below.
Gas pressure too low
What our technician checks
- Whether the gas supply valve is open, and bleeding the gas line
- The gas supply pressure measured, and the gas supplier told if it is too low
- The combined gas valve and its strainer, replaced if needed
- The ignition unit during ignition: 230 V between X18.1 and X18.3 of the BCU
- The ionisation electrode: gap, fouling and connection