Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Viessmann Fault code Viessmann
F.142

Communication fault with the fan unit

Breakdown: the boiler is stopped

The fan unit no longer communicates over the boiler's internal CAN bus. The burner goes into fault: the boiler stops heating and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F.142?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.142

The meaning depends on the boiler: find yours below.

F.142

Communication fault of the fan unit

Breakdown: the boiler is stopped Vitodens One Base

What our technician checks

  • Message F.342, to be cleared first if also present
  • Switching the appliance off for at least 2 minutes
  • The internal CAN bus cable: plug X4 on the HMU and the BCU, connection X1 (100A) on the BCU and the fan unit
  • Seating of plugs and wires, contact corrosion and cable condition
  • Bus termination: one 120 Ω resistor on the first and the last participant
  • The resistance between CAN L and CAN H: 60 Ω ±10 %
  • The faulty fan unit, to be replaced

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.