Communication fault with the fan unit
Breakdown: the boiler is stopped
The fan unit no longer communicates over the boiler's internal CAN bus. The burner goes into fault: the boiler stops heating and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.142?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.142
The meaning depends on the boiler: find yours below.
Communication fault of the fan unit
What our technician checks
- Message F.342, to be cleared first if also present
- Switching the appliance off for at least 2 minutes
- The internal CAN bus cable: plug X4 on the HMU and the BCU, connection X1 (100A) on the BCU and the fan unit
- Seating of plugs and wires, contact corrosion and cable condition
- Bus termination: one 120 Ω resistor on the first and the last participant
- The resistance between CAN L and CAN H: 60 Ω ±10 %
- The faulty fan unit, to be replaced