Viessmann Fault code Viessmann
F.14

Outdoor temperature sensor short circuit

Blocking: it retries by itself

The outdoor temperature sensor is short-circuited, in the sensor or in its cable. The boiler keeps heating, but it regulates as if it were 0 °C outside, whatever the real weather, until our technician has repaired the fault.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.14?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.14

The meaning depends on the boiler: find yours below.

F.14

Short circuit of the outside temperature sensor

Blocking: it retries by itself Vitodens One Base

What our technician checks

  • The outdoor sensor and its connection to terminals 1 and 2 (sensor 1) of the HMU electronic module
  • Seating of plugs and wires, contact corrosion and cable condition
  • The sensor resistance (NTC 10 kΩ), compared with its curve
  • The faulty part, replaced

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.