Solar collector temperature sensor short circuit
Blocking: it retries by itself
The sensor that measures the solar collector temperature is short-circuited, in the sensor or in its cable. The boiler keeps heating, but the solar system no longer heats hot water or supports the heating until our technician has repaired the sensor.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.12?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.12
The meaning depends on the boiler: find yours below.
Short circuit of the collector temperature sensor
What our technician checks
- Connection TS2 (plug 6) on the ADIO (EM-S1 extension) or SDIO/SM1A electronic module
- Seating of plugs and wires, contact corrosion and cable condition
- The sensor resistance (NTC 10 kΩ), compared with its curve
- The sensor, replaced if faulty