Vaillant Fault code Vaillant
F.685

Communication lost with the system control

Breakdown: the boiler is stopped

On an aroTHERM (VWL ../2 A, ../3 A), flexoTHERM exclusive or flexoCOMPACT exclusive heat pump, there is no longer any communication with the system control over the eBUS link: on the aroTHERM the heat pump is not connected to the control or the polarity is reversed; on the flexoTHERM the link with a system control that was already recognised has been interrupted. This is a fault: the heat pump no longer works normally (depending on the fault, it may keep running in emergency mode) and our technician has to find the cause.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.685?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.685

The meaning depends on the boiler: find yours below.

F.685

Communication error: eBus evaporator condenser

Breakdown: the boiler is stopped aroTHERM VWL ../2 A, ../3 A
F.685

Connection fault: controller not detected

Breakdown: the boiler is stopped flexoTHERM exclusive VWF ../4

What our technician checks

  • The eBUS link between the heat pump and the system control
  • The polarity of the eBUS connection