Vaillant Fault code Vaillant
F.532

Heating circuit flow rate too low

Breakdown: the boiler is stopped

On an aroTHERM (VWL ../2 A, ../3 A), flexoTHERM exclusive or flexoCOMPACT exclusive heat pump, too little water flows through the heating circuit: air in the circuit, a blocked filter, lack of water, closed taps or valves, a faulty circulation pump or, on the flexoTHERM, a fouled condenser. This is a fault: the heat pump no longer works normally (depending on the fault, it may keep running in emergency mode) and our technician has to find the cause.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.532?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.532

The meaning depends on the boiler: find yours below.

F.532

Building circuit: flow too low

Breakdown: the boiler is stopped aroTHERM VWL ../2 A, ../3 A, flexoTHERM exclusive VWF ../4

What our technician checks

  • Bleeding the heating circuit
  • The shut-off taps, the thermostatic valves and the bypass
  • The return dirt filter, in place and clean
  • The amount of water in the heating circuit
  • The heating circuit pump and its wiring
  • The measured flow rate: at least 35% of the nominal flow (flexoTHERM), read in the sensor and actuator test (aroTHERM)
  • The condenser (fouling)