Heating circuit flow rate too low
Breakdown: the boiler is stopped
On an aroTHERM (VWL ../2 A, ../3 A), flexoTHERM exclusive or flexoCOMPACT exclusive heat pump, too little water flows through the heating circuit: air in the circuit, a blocked filter, lack of water, closed taps or valves, a faulty circulation pump or, on the flexoTHERM, a fouled condenser. This is a fault: the heat pump no longer works normally (depending on the fault, it may keep running in emergency mode) and our technician has to find the cause.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.532?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.532
The meaning depends on the boiler: find yours below.
Building circuit: flow too low
What our technician checks
- Bleeding the heating circuit
- The shut-off taps, the thermostatic valves and the bypass
- The return dirt filter, in place and clean
- The amount of water in the heating circuit
- The heating circuit pump and its wiring
- The measured flow rate: at least 35% of the nominal flow (flexoTHERM), read in the sensor and actuator test (aroTHERM)
- The condenser (fouling)