Domestic hot water operation error
Breakdown: the boiler is stopped
On an Ecodan FTC5, FTC6 or FTC7 heat pump, LJ reports a domestic hot water operation error on systems whose hot water goes through an external plate heat exchanger, and on the F generation a domestic hot water operation error without that detail: disconnected tank sensor (thermistor THW5, or THW5B from FTC6 on), reduced flow or circulation pump. It is a fault that does not clear by itself: our technician clears the code (reset) once the cause has been found.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show LJ?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code LJ
The meaning depends on the boiler: find yours below.
DHW operation error (type of external plate HEX)
DHW operation error
What our technician checks
- The DHW tank water temperature thermistor (THW5 on FTC5, THW5B later), possibly disconnected
- The flow rate of the domestic water circuit
- The circulation pumps (primary and domestic)