Ferroli Fault code Ferroli
F14

Flue gas too hot or sensor fault

Blocking: it retries by itself

On a Bluehelix Top RRT K 50, F14 means the flue gases are too hot; on an Econcept 25, 35, 50 A or Kombi 35, a fault of the outdoor sensor (optional), and on an Econcept 51 A, a fault of flow sensor 2. In all three cases it is a temporary block: the boiler stops and starts again by itself once the value is back to normal.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.
  3. Do not reset the boiler: call us.

Does your boiler show F14?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F14

The meaning depends on the boiler: find yours below.

F14

High flue gas temperature

Blocking: it retries by itself Bluehelix Top RRT K 50
F14

External probe fault

Blocking: it retries by itself Econcept
F14

Flow sensor 2 fault

Blocking: it retries by itself Econcept 51 A

What our technician checks

  • The heat exchanger (Bluehelix Top RRT K 50)
  • The flue gas sensor (Bluehelix Top RRT K 50)
  • The flue material parameter (Bluehelix Top RRT K 50)
  • The outdoor sensor wiring, and the sensor, replaced if needed (Econcept)
  • The wiring of flow sensor 2, or the sensor, to be replaced (Econcept 51 A)