Heating water too hot
Blocking: it retries by itself
On a Bluehelix Top RRT K 50 and on an Econcept 25, 35, 50 A or Kombi 35, the water going out to the heating is too hot and the overheating protection stops the burner, usually because the water is not circulating well (pump, air in the system, blocked water filter) or because of the flow sensor. It is a temporary block: the boiler starts again by itself once the temperature is back to normal.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F08?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F08
The meaning depends on the boiler: find yours below.
Overtemperature protection tripped
System flow overtemperature
What our technician checks
- The flow sensor: position, operation, replacement if needed
- The circulation pump, to be freed (cap removed, shaft turned with a screwdriver) or replaced
- Bleeding the air from the system (Bluehelix Top RRT K 50)
- The water filters of the system (Econcept)