Fan, flue or water pressure fault
Blocking: it retries by itself
The meaning depends on the boiler: on a Bluehelix Alpha or HiTech RRT the fan is not working properly; on a New Elite 60 the flue gas outlet monitoring (air pressure switch) has tripped; on an Econcept 25, 35, 50 or Kombi 35 the system water pressure is too low. In every case the boiler stops temporarily and restarts by itself once everything is back to normal.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Econcept 25, 35, 50 or Kombi 35: with the boiler cold, bring the pressure back to 1 to 1.5 bar with the filling tap, then close it again.
- Do not reset the boiler: call us.
Does your boiler show F05?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F05
The meaning depends on the boiler: find yours below.
Fan fault
Flue gas thermostat tripped
Insufficient system water pressure
The boilers that show this code
What our technician checks
- Bluehelix: the wiring of the fan's 5-pin connector
- The fan, replaced if needed
- New Elite 60: the flue duct (blockage)
- New Elite 60: the air pressure switch
- Econcept: filling the system
- Econcept: the water pressure switch wiring; its contact must close at 1.5 bar