Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Ferroli Fault code Ferroli
F05

Fan, flue or water pressure fault

Blocking: it retries by itself

The meaning depends on the boiler: on a Bluehelix Alpha or HiTech RRT the fan is not working properly; on a New Elite 60 the flue gas outlet monitoring (air pressure switch) has tripped; on an Econcept 25, 35, 50 or Kombi 35 the system water pressure is too low. In every case the boiler stops temporarily and restarts by itself once everything is back to normal.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Econcept 25, 35, 50 or Kombi 35: with the boiler cold, bring the pressure back to 1 to 1.5 bar with the filling tap, then close it again.
  3. Do not reset the boiler: call us.

Does your boiler show F05?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F05

The meaning depends on the boiler: find yours below.

F05

Fan fault

Blocking: it retries by itself Bluehelix Alpha, Bluehelix HiTech RRT C
F05

Flue gas thermostat tripped

Blocking: it retries by itself New Elite 60
F05

Insufficient system water pressure

Blocking: it retries by itself Econcept

The boilers that show this code

What our technician checks

  • Bluehelix: the wiring of the fan's 5-pin connector
  • The fan, replaced if needed
  • New Elite 60: the flue duct (blockage)
  • New Elite 60: the air pressure switch
  • Econcept: filling the system
  • Econcept: the water pressure switch wiring; its contact must close at 1.5 bar

Related codes