Ferroli Fault code Ferroli
A04

No flame or flue safety trip

Breakdown: the boiler is stopped

On an Econcept 25, 35, 50 A or Kombi 35, A04 means there is no flame after the ignition phase (air or flue ducts blocked, blocked siphon, ionisation electrode, unstable flame or gas valve setting); on an Econcept 51 A, the flue safety device has tripped because the flue gases were too hot (code F07) three times in 24 hours. In both cases the boiler is locked out and, for safety, it must not be reset before our technician has been.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Do not reset the boiler: call us.

Does your boiler show A04?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code A04

The meaning depends on the boiler: find yours below.

A04

No flame after the ignition phase

Breakdown: the boiler is stopped Econcept
A04

Flue exhaust safety device tripped

Breakdown: the boiler is stopped Econcept 51 A

What our technician checks

  • The chimney, flue ducts, air inlet and terminals, to be cleared
  • The condensate siphon, cleaned if needed (Econcept)
  • The position of the ionisation electrode, replaced if needed (Econcept)
  • The burner (Econcept)
  • The gas valve Offset setting at minimum output (Econcept)
  • The position and operation of the flue gas sensor (Econcept 51 A)