ACV Fault code ACV
4

No flame at ignition

Breakdown: the boiler is stopped

The burner did not light: the boiler saw no flame (on the Kombi Kompakt HR, after 4 ignition attempts), for example because the gas tap is closed or the gas pressure is too low. It is a fault: the boiler locks out and waits for a reset, whereas a steady 4 on the service display is only the normal ignition phase.

What you can do

  1. Write down the code shown and the boiler model, without opening the appliance.
  2. Check that the boiler's gas tap is open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 4?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 4

The meaning depends on the boiler: find yours below.

4

No flame signal after 4 ignition attempts

Breakdown: the boiler is stopped Kombi Kompakt HR
4

No flame signal

Breakdown: the boiler is stopped Kompakt HRE

What our technician checks

  • The gas tap, which must be open
  • The gas supply pressure, neither too low nor cut off
  • The gas line, bled if there is air in it
  • The ignition gap of the electrode
  • The power supply to the gas valve and the ignition unit
  • The ignition electrode, the spark plug cap and the ignition unit, replaced if needed
  • The gas-air setting