No flame at ignition
Breakdown: the boiler is stopped
The burner did not light: the boiler saw no flame (on the Kombi Kompakt HR, after 4 ignition attempts), for example because the gas tap is closed or the gas pressure is too low. It is a fault: the boiler locks out and waits for a reset, whereas a steady 4 on the service display is only the normal ignition phase.
What you can do
- Write down the code shown and the boiler model, without opening the appliance.
- Check that the boiler's gas tap is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 4?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 4
The meaning depends on the boiler: find yours below.
No flame signal after 4 ignition attempts
No flame signal
What our technician checks
- The gas tap, which must be open
- The gas supply pressure, neither too low nor cut off
- The gas line, bled if there is air in it
- The ignition gap of the electrode
- The power supply to the gas valve and the ignition unit
- The ignition electrode, the spark plug cap and the ignition unit, replaced if needed
- The gas-air setting