Boiler temperature too high
Breakdown: the boiler is stopped
The boiler is overheating because the water is not circulating well: air in the system, a pump that is not running, closed radiators or a pump set too low (Kombi Kompakt HR: the 1 blinks on the service display; other Kompakt boilers: 1 on the temperature display, red light blinking). It is a fault: the boiler locks out and waits for a reset, whereas a steady 1 on the service display only means the requested temperature has been reached.
What you can do
- Write down the code shown and the boiler model, without opening the appliance.
- Check that the radiator valves are open.
- Check the water pressure on the temperature display, with the boiler switched off and cold: 1 to 2 bar. Too low? Top up and bleed the radiators, as your installer showed you.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 1?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 1
The meaning depends on the boiler: find yours below.
Temperature too high
What our technician checks
- Air in the system, to be bled
- The pump, which must be running
- Circulation in the system: open radiators and the pump setting
- The flow switch, which can stick (Dutch edition of the Kompakt HRE manual)