Temperature sensor fault
Breakdown: the boiler is stopped
One of the boiler's temperature sensors is faulty: on a Kombi Kompakt HR, the 0 blinks on the service display and the temperature display names the sensor (1: flow sensor S1, 2: return sensor S2, 3: hot water sensor S3, no number: fault found during the self-test); on the other Kompakt boilers (HRE, HR eco, Solo HR), the 0 shows on the temperature display while the red light blinks, and always means a fault found during the self-test. It is a fault: the boiler locks out and waits for a reset, whereas a steady 0 on the service display is only the normal pump overrun after heating.
What you can do
- Write down the code shown and the boiler model, without opening the appliance.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 0?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 0
The small number shown beside the code tells which.
Sensor failure after self-check
Sensor S1 failure
Sensor S2 failure
DHW sensor S3 failure
What our technician checks
- The wiring of the sensor shown (S1, S2 or S3), for a break (Kombi Kompakt HR)
- The sensor shown (S1, S2 or S3), replaced (Kombi Kompakt HR)
- After a self-test fault: sensors S1 and/or S2, replaced