ACV Fault code ACV
2x

Oil burner: no flame at start-up

Breakdown: the boiler is stopped

The red light of the BMV oil burner (Delta Pro S and Delta Pro Pack on oil, Delta FV) blinks 2 times: at the end of the safety time no flame formed, for example for lack of oil or because of the oil valves, the flame detector, the ignition or the burner setting. It is a fault: the burner goes to safety lockout and only restarts after a reset.

What you can do

  1. Write down the code shown and the boiler model, without opening the appliance.
  2. Check that there is no power cut and that there is still heating oil in the tank.
  3. Wait five minutes before resetting: the RESET button is on the burner.
  4. Reset the boiler once only.
  5. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 2x?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 2x

The meaning depends on the boiler: find yours below.

2x

No flame formed at the end of the safety time

Breakdown: the boiler is stopped BMV

What our technician checks

  • The oil valves: cleaned if dirty, replaced if faulty
  • The flame detector: cleaned if dirty, replaced if faulty
  • The presence of oil
  • The burner setting
  • The ignition device, replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.