Mitsubishi Electric Fault code Mitsubishi Electric
J9

Communication failure between FTC (Main) and FTC (Sub)

Breakdown: the boiler is stopped

In an Ecodan system with several outdoor units (FTC6, FTC7 or F generation controller), the main control board, the FTC (Main), has lost communication with one of the sub boards, the FTC (Sub), which each run one outdoor unit. It is a fault, not normal operation: the code stays on until our technician has checked the link between the boards and cleared the code.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show J9?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code J9

The meaning depends on the boiler: find yours below.

J9

Communication failure between FTC(Main) and FTC(Sub).

Breakdown: the boiler is stopped Ecodan FTC6
J9

Communication failure between FTC (Main) and FTC (Sub).

Breakdown: the boiler is stopped Ecodan F generation, Ecodan FTC7

What our technician checks

  • The connection cable between FTC (Main) and FTC (Sub): damage or loose connections
  • The daisy-chain wiring of the RC terminals (TBI.6 on FTC6, TB5 on FTC7 and F generation), 10 m at most between two units
  • At least 5 cm between this cable and the power cables (electrical noise)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.