Communication failure between FTC (Main) and FTC (Sub)
Breakdown: the boiler is stopped
In an Ecodan system with several outdoor units (FTC6, FTC7 or F generation controller), the main control board, the FTC (Main), has lost communication with one of the sub boards, the FTC (Sub), which each run one outdoor unit. It is a fault, not normal operation: the code stays on until our technician has checked the link between the boards and cleared the code.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show J9?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code J9
The meaning depends on the boiler: find yours below.
Communication failure between FTC(Main) and FTC(Sub).
Communication failure between FTC (Main) and FTC (Sub).
What our technician checks
- The connection cable between FTC (Main) and FTC (Sub): damage or loose connections
- The daisy-chain wiring of the RC terminals (TBI.6 on FTC6, TB5 on FTC7 and F generation), 10 m at most between two units
- At least 5 cm between this cable and the power cables (electrical noise)